Product Overview
The EKPC pure sine wave power inverter charger is an advanced power solution that combines the functions of a pure sine wave inverter and a charging system.
Power Range
It has a wide power range, from 500W to 5000W, with a peak power of up to 10000W, which can meet the power consumption needs of different scenarios.
Input and Output Parameters
Input Voltage: Supports 12V/24V/48VDC.
Output Voltage: Is 110/220VAC ± 5%.
USB Output: Provides an output of 5V2A.
Frequency: Switchable between 50Hz/60Hz, with a frequency fluctuation range of ± 3Hz.
Protection Functions
It has various protection functions such as undervoltage, overvoltage, overload, overheating, short circuit, and reverse connection (fuse), effectively ensuring the safe and stable operation of the equipment.
Output Characteristics
The output waveform is a pure sine wave, which can provide stable and pure power for the equipment.
It has a soft start function to reduce the impact when the equipment is started.
Operating Temperature Range
It can operate normally in an environment from - 10°C to + 50°C.
Specific Parameters
The peak power of the 500W/1000W rated power is 1000W/2000W; the peak power of the 1500W/2000W/3000W rated power is 3000W/4000W/6000W; the peak power of the 4000W/5000W rated power is 8000W/10000W.
The ranges of different input voltages are as follows: 12V (10 - 15.5V); 24V (20 - 31V); 48V (40 - 61V).
The undervoltage alarm values are respectively: 12V (10.5V ± 0.5V); 24V (21V ± 0.5V); 48V (42V ± 1V).
The undervoltage protection values are respectively: 12V (10V ± 0.5V); 24V (20V ± 0.5V); 48V (40V ± 1V).
The undervoltage recovery values are respectively: 12V (12V ± 0.5V); 24V (24V ± 0.5V); 48V (48V ± 1V).
The overvoltage protection values are respectively: 12V (15.5V ± 0.5V); 24V (31V ± 0.5V); 48V (60V ± 1V).
The overvoltage recovery values are respectively: 12V (15V ± 0.5V); 24V (20V ± 0.5V); 48V (59V ± 1V).
This inverter charger has wide applicability and reliable performance, can provide stable power support for various equipment, and ensure the safe operation of the equipment under different working conditions.
GET A QUOTE